A solar system that carries the building all afternoon and then goes dark at 8 p.m. is one of the most common complaints installers hear. It is also one of the easiest faults to diagnose, because the inverter almost always records the reason before it shuts down.

This guide covers the six causes behind a night-time trip, what each looks like on the display, and the checks worth doing before you call anyone out.

Start with the fault code, not with the battery

Every hybrid inverter stores an event log. Before touching anything, read the last three fault records: the code, the time and the battery voltage at the moment of the trip. That single step separates a battery problem from an overload problem from a settings problem, and it saves hours of guessing.

If the log shows an undervoltage or low-battery code, the inverter is protecting the battery from being drained past its limit. If it shows an overload or over-temperature code, the problem is on the load side. Both look identical from the sitting room — everything goes off — but they need opposite fixes.

Cause 1: the battery is genuinely empty

The most common cause, and the least dramatic. A household adds a freezer, then a second air conditioner, then an extra fridge, and the battery bank that carried the original load now empties two hours after sunset. The inverter is doing its job.

Confirm it by comparing the energy the system produced during the day with the energy drawn after dark. Most inverters display daily yield and daily consumption. If night consumption is consistently higher than the usable battery capacity, the bank is undersized for the load — not faulty.

Cause 2: the discharge depth setting is too shallow

Lithium batteries are often shipped with a conservative depth-of-discharge limit, and some installers leave the factory value in place. A setting that stops discharge at 40 or 50 per cent state of charge will cut the night short even on a healthy battery. Check what the battery management system reports as its limit, and set the inverter to match the battery maker's data sheet — not a number copied from an internet forum.

Cause 3: the start-up surge is bigger than the battery can supply

Compressors and pumps draw several times their running current for a second or two. A battery bank can hold enough energy for the night and still fail at the instant a freezer compressor starts, because the instantaneous current exceeds what the battery management system will allow. The symptom is specific: the trip happens exactly when an appliance kicks in, and the battery state of charge is still comfortable.

The fix is not always a bigger battery. Soft-starting the load, staggering start times, or moving the largest motor to a circuit the inverter does not carry will often solve it at a fraction of the cost.

Cause 4: battery communication has dropped

Hybrid inverters rely on a data cable and a protocol setting to know what the battery is doing. If that link fails — a loose RJ45, a wrong protocol selected after a firmware update, a cable run next to power conductors — the inverter either falls back to voltage-based guesses or refuses to discharge. The display usually shows a communication or BMS fault code, and the battery's own indicator lights may show a healthy charge while the inverter believes otherwise.

Re-seat both ends of the cable, confirm the protocol number matches the battery maker's list, and check the log again after one night.

Cause 5: the inverter is overheating in a closed room

An inverter in a sealed store or a cupboard without ventilation runs hot all day and hotter under evening load. Many units derate first and then shut down. The trip then looks random but tends to happen on warm, still nights and after long afternoon runs.

Feel the air around the unit at the moment of failure, check that the fan actually spins, and clear at least the clearance the manual asks for on every side. This is a cheap fix that is very often skipped.

Cause 6: an earth fault or a failing appliance

A neutral-to-earth fault, damp outdoor wiring after rain, or a compressor with a failing winding can trip the inverter on a residual-current or overload protection. The pattern gives it away: the trip repeats at the same time each night, or only when one particular appliance is connected. Disconnect that circuit for one night to confirm before replacing anything.

What to check yourself, in order

  • Read and note the last three fault codes with their times.
  • Note battery voltage and state of charge at the moment of the trip.
  • Compare daily solar yield with nightly consumption on the display.
  • Confirm the battery's permitted depth of discharge against the inverter setting.
  • Listen for the trip at the instant an appliance starts, and note which one.
  • Check the ventilation and the fan.

If the fault code points to the battery and the numbers say the bank is simply too small, the honest answer is a capacity decision rather than a repair. Our application guides show how battery banks are sized for homes, cold rooms and pumping loads, and the diesel versus solar comparison helps when you are deciding whether to extend the battery or keep a generator for the heaviest hours.

What not to do

Do not raise the low-voltage cut-off to make the inverter stop tripping. That hides the symptom, deep-cycles the battery harder on the nights it does run, and shortens its life. Do not bypass the battery management system either: it is the only thing standing between an overload and a damaged bank.

A night-time trip is information, not bad luck. Read the log, match the code to the load, and the fix is usually obvious within an hour.

Frequently asked questions